CUT&RUN Optimization and Troubleshooting

Prev Next
This article also applies to CUT&Tag, meCUT&RUN and Multiomic CUT&RUN. EpiCypher’s CUTANATM Wash Buffer Enhancers ( EpiCypher 14-1803 ) are optional , optimized additives for all CUTANA assays, and can be ad...
We recommend adding E. coli Spike-in DNA ( EpiCypher 18-1401 ) to all CUT&RUN reactions for sequencing normalization. The spike-in DNA is added following pAG-MNase digestion, as part of the Stop Buffer. The major goal is for E. coli ...
Like all experiments, CUT&RUN requires thoughtful experimental design. Some steps may require user-specific optimization. For ease, we have broken these down into four main steps, outlined below. Step 1. Sample Preparation Number of Ce...
Below we outline the main areas of concern and general considerations for troubleshooting CUTANA™ CUT&RUN assays. For ALL troubleshooting, we recommend reviewing the basic quality control metrics in Figure 1 . What is your cel...
This article also applies to meCUT&RUN and Multiomic CUT&RUN. For CUTANA™ CUT&RUN assays, we recommend harvesting 500,000 cells per reaction plus 10% excess to account for sample loss. If your experiment requires fewer ...
For new targets and cell types, optimize CUT&RUN workflows as described in Figure 1 . CUT&RUN success depends on many factors, including cell type, cell number, target abundance, and antibody quality. Note that using low cell numbers m...
Signs of ConA bead damage include beads that are black in color, granular/grainy, or clumpy after mixing. This can happen if ConA beads are frozen. ConA beads are crucial to CUTANA™ workflows. They should be stored at 4˚C, appear brow...
This article also applies to meCUT&RUN and Multiomic CUT&RUN. ConA beads often become clumpy or sticky after overnight incubation at 4˚C. Some clumping is normal, and should not impact your data. However, if you start with a sample o...
This article also applies to meCUT&RUN and Multiomic CUT&RUN. There are several steps you can take to help prevent ConA bead clumping and precipitation.  Do NOT let ConA beads dry out. Avoid disturbing beads with pipette while ...
This article also applies to meCUT&RUN and Multiomic CUT&RUN. We do not recommend using TapeStation/Bioanalyzer or qPCR to evaluate raw CUT&RUN DNA, as they will NOT provide useful information at this step of the workflow. CUT&RU...
There are many factors to consider when troubleshooting low CUT&RUN DNA yields. Low yields are common for low abundance targets (e.g. H3K4me3), but also depend on the number/quality of starting cells, cell type, and antibody performance. If you...
Similar yields from H3K4me3 and IgG controls do NOT imply CUT&RUN failure. H3K4me3 is a low abundance target, resulting in lower yields that are often similar to IgG. In these cases, use the total amount of CUT&RUN-enriched DNA for library ...