--- title: "How can I figure out the ideal Hia5 ratio for my project?" slug: "how-can-i-figure-out-the-ideal-hia5-ratio-for-my-project" updated: 2026-05-12T12:00:01Z published: 2026-05-12T12:00:01Z canonical: "support.epicypher.com/how-can-i-figure-out-the-ideal-hia5-ratio-for-my-project" --- > ## Documentation Index > Fetch the complete documentation index at: https://support.epicypher.com/llms.txt > Use this file to discover all available pages before exploring further. # How can I figure out the ideal Hia5 ratio for my project? In human cells, we have found that the Hia5:nuclei ratio detailed in the Fiber-seq [manual](https://www.epicypher.com/wp-content/uploads/fiber-seq-kit-manual_v1.pdf) is ideal for obtaining optimal 6mA labeling (~6% labeling across the entire human genome). However, when working with a new species or unique conditions, it may be worthwhile to run an optimization experiment to experimentally determine this ratio in your sample type, as outlined below: ### Recommended Workflow #### 1. Perform a 3-Point Cell Titration To determine the optimal conditions for 6mA labeling, set up three parallel Fiber-seq reactions using varying nuclei inputs: - **500,000 nuclei** (or 0.5× the standard input based on your cell’s genome—see more on standard inputs [here](/v1/docs/what-samples-and-cell-types-are-compatible-with-fiber-seq)) - **1,000,000 nuclei** (or the standard input based on your cell’s genome) - **2,000,000 nuclei** (or 2× the standard input based on your cell’s genome) This range allows you to assess how input quantity impacts labeling efficiency and overall data quality. #### 2. Run Fiber-seq Reactions Process each condition independently through the full Fiber-seq workflow, including library prep. Be sure to keep all other variables consistent across reactions to ensure that differences in output are attributable to input amount. #### 3. Perform Shallow Sequencing Sequence each sample at approximately **~1× coverage**. This level of sequencing is sufficient to evaluate 6mA labeling efficiency without committing to a full-depth run. For more on QC sequencing, see our section on it [here](http://support.epicypher.com/fiber-seq/shallow-qc-sequencing-for-fiber-seq). #### 4. Evaluate % 6mA Labeling Analyze the sequencing data to determine the **percentage of 6mA incorporation** for each condition. This metric serves as a key indicator of labeling efficiency. - Identify the input condition that provides **optimal labeling** (e.g., strong signal without over-labeling or signal saturation—in human cells, EpiCypher finds that 6% labeling achieves these goals). - Consider overall data quality in addition to % 6mA when selecting conditions. #### 5. Proceed with Final Experiment Once the optimal input amount has been determined, use those conditions for your full-scale Fiber-seq experiment. ### Additional Considerations - **Limited or precious samples:** If your sample availability is constrained, consider performing the titration using a **closely related cell type**. This can provide a useful approximation for optimizing conditions while preserving your primary material. - **Enzyme titration option:** In addition to varying cell input, you may also perform a titration of the **Hia5 methyltransferase concentration**: This can help fine-tune labeling efficiency, particularly if cell input is fixed or limited. - 0.5× standard concentration - 1× standard concentration - 2× standard concentration By incorporating a brief titration step into your workflow, you can significantly improve the reliability and interpretability of your Fiber-seq results.