--- title: "A ChIP-seq User’s Guide to Getting Started with CUT&RUN" slug: "chip-seq-users-guide-to-getting-started-with-cut-and-run" tags: ["chip-seq", "cut and run", "Getting started"] updated: 2026-11-09T15:55:39Z published: 2026-11-09T15:55:39Z canonical: "support.epicypher.com/chip-seq-users-guide-to-getting-started-with-cut-and-run" --- > ## Documentation Index > Fetch the complete documentation index at: https://support.epicypher.com/llms.txt > Use this file to discover all available pages before exploring further. # A ChIP-seq User’s Guide to Getting Started with CUT&RUN If your lab already has an established ChIP-seq workflow, you have a major advantage when getting started with CUT&RUN: you already know your targets, your expected biology, and what good chromatin profiling data should look like. CUT&RUN can answer many of the same questions as ChIP-seq, but the experimental workflow is substantially different. This guide highlights the main differences ChIP-seq users should know before running their first CUT&RUN experiment. ## What does CUT&RUN offer that ChIP-seq doesn't? - No sonication: ChIP-seq requires bulk chromatin to be fragmented before immunoprecipitation, and achieving consistent fragmentation can require substantial optimization. Sonication efficiency can vary with cell type, cell number, fixation conditions, buffer composition, sonicator, and instrument settings, while differences in chromatin structure can make some genomic regions more susceptible to mechanical shearing than others [1,2]. CUT&RUN eliminates this source of technical variability by using antibody-tethered MNase to selectively cleave DNA surrounding the target directly in intact nuclei [3,4]. There is no need to optimize sonication conditions or generate a specific chromatin fragment-size distribution before proceeding with the assay. - No immunoprecipitation: ChIP-seq fragments and solubilizes the entire genome and then relies on immunoprecipitation to enrich a relatively small population of target-associated DNA from that complex mixture. This creates opportunities for nonspecific DNA recovery and background. CUT&RUN takes the opposite approach: antibody-tethered MNase selectively cleaves and releases DNA surrounding the target, while the vast majority of genomic DNA is left behind [3,4]. This targeted release produces exceptionally low background and contributes to the higher signal-to-noise and lower sequencing requirements reported for CUT&RUN compared with ChIP-seq [3]. - Less optimization: ChIP-seq contains several technically demanding steps that can require optimization for different sample types and targets, including formaldehyde cross-linking, chromatin extraction and solubilization, sonication, antibody conditions, and immunoprecipitation. Published ChIP-seq studies have noted that fixation, buffer composition, and sonication conditions may require iterative, sample-specific optimization, increasing the time, material, and cost needed to establish a robust workflow [1,5]. CUT&RUN removes several of these variables: it is typically performed without cross-linking and does not require bulk chromatin solubilization, sonication, or immunoprecipitation [3,4]. Although antibody concentration and other assay conditions still need to be validated, eliminating multiple challenging steps can make CUT&RUN substantially easier to establish and reproduce.ChIP itself can also generate misleading enrichment. Teytelman et al. demonstrated that highly expressed genomic regions can produce apparent ChIP enrichment for unrelated proteins, highlighting how ChIP-associated background can sometimes be mistaken for genuine protein localization. - Below is an overview of the two protocols highlighting their similarities and differences. You can also read more in [this blog](https://www.epicypher.com/resources/blog/still-using-chip-try-cutrun-for-enhanced-chromatin-profiling/) or [this article](/v1/docs/run-vs-chip-seq). ## What parts of my ChIP-seq workflow can I keep? Although the wet-lab assay changes when switching to CUT&RUN, much of your existing ChIP experience is still useful: - Your targets: CUT&RUN is commonly used to profile both histone modifications and chromatin-associated proteins, including transcription factors. For a first experiment, it is often useful to choose a target you already know well from ChIP-seq. Existing data then provide a reference when evaluating your CUT&RUN results. - Your sequencing infrastructure: CUT&RUN libraries are compatible with standard Illumina sequencing workflows. In fact, because CUT&RUN has very low background, substantially fewer reads are generally needed than for ChIP-seq. For most CUT&RUN experiments, approximately 10–15 million reads per reaction are sufficient, although requirements vary by target. - Many of your analysis tools: A completely new analysis environment is not required. CUT&RUN data can be visualized using familiar tools such as IGV and deepTools, and peak callers including SEACR and MACS2 are commonly used. There are important differences in how CUT&RUN data should be processed and evaluated, so we do not recommend treating CUT&RUN data exactly like ChIP-seq data. However, researchers already familiar with ChIP-seq analysis will recognize much of the overall workflow. ## Can I compare CUT&RUN data with my existing ChIP-seq data? Yes. In fact, an established ChIP-seq dataset can be especially useful when evaluating your first CUT&RUN experiment. Your CUT&RUN and ChIP-seq tracks will not necessarily look identical—the two methods enrich target-associated DNA differently, and differences in background, peak shape, and signal intensity are expected. Instead of expecting an exact match, compare whether the assays recover the same underlying biology. For example: - Are known target loci enriched? - Are major genomic features consistent between datasets? - Do positive and negative regions behave as expected? - Is background reduced in the CUT&RUN data? - Are the same overall biological conclusions supported? If you’d like to test-drive the analysis before trying a CUT&RUN assay in your own lab, publicly available datasets and tutorials include: - [https://www.cell.com/star-protocols/fulltext/S2666-1667(21)00457-3](https://www.cell.com/star-protocols/fulltext/S2666-1667(21)00457-3) - [https://pubmed.ncbi.nlm.nih.gov/39760380/](https://pubmed.ncbi.nlm.nih.gov/39760380/) - [https://github.com/nf-core/cutandrun](https://github.com/nf-core/cutandrun) - [https://nbis-workshop-epigenomics.readthedocs.io/en/latest/content/tutorials/quantitativeChip/cut-and-run-data.html](https://nbis-workshop-epigenomics.readthedocs.io/en/latest/content/tutorials/quantitativeChip/cut-and-run-data.html) - [https://www.ncbi.nlm.nih.gov/geo/query/acc.cgi](https://www.ncbi.nlm.nih.gov/geo/query/acc.cgi) You can also read more about this topic [here](http://support.epicypher.com/docs/can-i-compare-cut-run-data-to-existing-chip-seq-datasets). ## What controls should I use? CUT&RUN does not use a traditional ChIP-seq input control. Instead, we recommend including an IgG negative control to measure nonspecific background cleavage. A positive control antibody is also especially useful when establishing the assay because it helps distinguish an assay-level problem from poor performance of the experimental antibody. EpiCypher's CUTANA™ CUT&RUN Kit includes positive and negative control antibodies as well as SNAP-CUTANA™ spike-in controls for monitoring assay performance. You can read more about controls in CUT&RUN experiments [here](https://support.epicypher.com/docs/assay-optimization-and-troubleshooting-cut-and-run). ## What should my first CUT&RUN experiment look like? For your first experiment, keep as many variables familiar as possible. We recommend starting with: - A sample type you already know how to handle - A well-characterized target - An antibody with CUT&RUN validation or published CUT&RUN use - Appropriate positive and negative controls - Existing ChIP-seq data, if available, for comparison A first CUT&RUN experiment does not need to reproduce an entire ChIP-seq study. A small pilot using a familiar target is often enough to evaluate data quality, background, workflow, and sequencing requirements in your own lab. If you already have ChIP-seq data for that target, you also have a built-in benchmark. ## I don't have CUT&RUN set up in my lab. Can I try it first? Yes. You don't necessarily need to establish CUT&RUN from scratch to determine whether it will work for your samples: using a service or core can be a useful way to generate initial CUT&RUN data before bringing the workflow into your own laboratory. A growing number of academic core facilities now offer CUT&RUN services at varying entry points into the workflow. Examples include*: - Yale Pathology Epigenomics Core: offers high-throughput CUT&RUN assays, including automated assay execution and library generation. - Weill Cornell Medicine Epigenomics Core: offers CUT&RUN library generation for studying protein-DNA interactions. - Baylor College of Medicine CPRIT Comprehensive Cancer Epigenomics Core Facility: includes CUT&RUN among its bulk epigenomics services. - EpiCypher also offers end-to-end CUT&RUN Services, including antibody testing. To read more or inquire about our services, visit our [Services](https://www.epicypher.com/services/cutana-cutrun-services/) page. *Are you a core facility offering CUT&RUN services and would like to be featured on this list? Email us at [techsupport@epicypher.com](mailto:techsupport@epicypher.com)! ## Learn more - [ChIP-seq vs. CUT&RUN vs. CUT&Tag: Which should you use?](https://www.epicypher.com/resources/blog/chip-seq-vs-cutrun-vs-cuttag-which-should-you-use/) - [The 8 Basic Steps of CUT&RUN](/v1/docs/8-basic-steps-of-cut-and-run) - [What is the difference between CUT&RUN and ChIP-seq?](/v1/docs/run-vs-chip-seq) - [How do I optimize CUT&RUN for new targets or cell types?](/v1/docs/optimize-cut-and-run-targets-cells) ## References 1. Landt SG et al. (2012). ChIP-seq guidelines and practices of the ENCODE and modENCODE consortia. Genome Research 22:1813–1831. 2. Meyer CA & Liu XS (2014). Identifying and mitigating bias in next-generation sequencing methods for chromatin biology. Nature Reviews Genetics 15:709–721. 3. Skene PJ, Henikoff JG & Henikoff S (2018). Targeted in situ genome-wide profiling with high efficiency for low cell numbers. Nature Protocols 13:1006–1019. 4. Skene PJ & Henikoff S (2017). An efficient targeted nuclease strategy for high-resolution mapping of DNA binding sites. eLife 6:e21856. 5. Arrigoni L et al. (2016). Standardizing chromatin research: a simple and universal method for ChIP-seq. Nucleic Acids Research 44:e67.